To speed up the troubleshooting procedure, check the state of the power indicator LEDs
on the various circuit boards.
(1)
Place the tester probes across the ends of the cable from the alternator. The measured voltage
should be approximately 15-17 VDC at a speed of about 30 RPM.
(2
)
As for step (1) but across pins 1 and 2 of connector CN3 on the brake board.
(3)
Using a tester, check that all the output voltages on connector CN1 of the brake board are
correct, referring to paragraph 2.9. "Cables".
(4
)
As for step (3) but on connector CN1 of the display board.