Table 19. Event IDs and codes (continued)
Notification
Event ID
type
060002
W
060003
W
062001
W
062002
W
062003
W
072900
E
072901
E
072911
E
073003
E
073005
E
073006
W
073007
W
073305
E
073310
E
074001
W
074002
E
076001
E
076002
E
076401
E
076402
E
076403
E
076501
E
076502
E
076503
E
076504
E
076505
E
076511
E
076512
E
076513
E
076514
E
079000
W
74
Storwize V7000 Version 6.1.0: Troubleshooting, Recovery, and Maintenance Guide
Condition
The thin-provisioned volume copy is offline because the metadata is
corrupt.
The thin-provisioned volume copy is offline because the repair has failed. 1860
Unable to mirror medium error during volume copy synchronization
The mirrored volume is offline because the data cannot be synchronized.
The repair process for the mirrored disk has stopped because there is a
difference between the copies.
There was a PCIe link failure between canisters.
The PCIe link is degraded between canisters.
The PCIe link for the CPU is degraded.
The fibre-channel ports are not operational.
An active fibre-channel port cannot detect a node in the cluster. No active
PCIe connection exists to the node that cannot be detected.
The SAN is not correctly zoned. As a result, more than 512 ports on the
SAN have logged into one Storwize V7000 port.
There are fewer fibre-channel ports operational than are configured.
One or more fibre-channel ports are running at a speed that is lower than
the last saved speed.
A duplicate fibre-channel frame has been detected, which indicates that
there is an issue with the fibre-channel fabric. Other fibre-channel errors
might also be generated.
Unable to determine the vital product data (VPD) for an FRU. This is
probably because a new FRU has been installed and the software does
not recognize that FRU. The cluster continues to operate; however, you
must upgrade the software to fix this warning.
The node warm started after a software error.
The internal disk for a node has failed.
The hard disk is full and cannot capture any more output.
One of the two power supply units in the node has failed.
One of the two power supply units in the node cannot be detected.
One of the two power supply units in the node is without power.
A high-speed SAS adapter is missing.
Degraded PCIe lanes on a high-speed SAS adapter.
A PCI bus error occurred on a high-speed SAS adapter.
A high-speed SAS adapter requires a PCI bus reset.
Vital product data (VPD) is corrupt on high-speed SAS adapter.
A high-speed SAS controller is missing.
Degraded PCIe lanes on a high-speed SAS adapter.
A PCI bus error occurred on a high-speed SAS adapter.
A high-speed SAS adapter requires a PCI bus reset.
Data has not been recovered on volumes.
Error
code
1862
1950
1870
1600
1006
1052
1034
1060
1550
1800
1061
1065
1203
2040
2030
1030
2030
1096
1096
1097
1120
1121
1121
1122
1121
1032
1032
1032
1034
1850

Advertisement