Table 19. Event IDs and codes (continued)
Notification
Event ID
type
010022
W
010023
W
010024
W
010025
W
010026
E
010027
E
010028
W
010029
E
010030
E
010031
E
010032
W
010033
E
010034
E
010035
W
010040
E
010041
E
010042
E
010043
E
010044
E
010050
E
010051
E
010052
E
010053
E
010054
E
010055
E
010056
E
010057
E
010058
E
010059
E
010060
E
010061
E
70
Storwize V7000 Version 6.1.0: Troubleshooting, Recovery, and Maintenance Guide
Condition
There are too many managed disks presented to the cluster.
There are too many LUNs presented to a node.
There are too many drives presented to a node.
A disk I/O medium error has occurred.
There are no managed disks that can be used as a quorum disk.
The quorum disk is not available.
A controller configuration is not supported.
A login transport fault has occurred.
A managed disk error recovery procedure (ERP) has occurred. The node
or controller reported the following:
v Sense
v Key
v Code
v Qualifier
One or more MDisks on a controller are degraded.
The controller configuration limits failover.
The controller configuration uses the RDAC mode; this is not supported.
Persistent unsupported controller configuration.
A quorum disk is configured on the controller that is set to not allow
quorum.
The controller system device is only connected to the node through a
single initiator port.
The controller system device is only connected to the node through a
single target port.
The controller system device is only connected to the cluster nodes
through a single target port.
The controller system device is only connected to the cluster nodes
through half of the expected target ports.
The controller system device has disconnected all target ports to the
cluster nodes.
A solid-state drive (SSD) failed. A rebuild is required.
A solid-state drive (SSD) is missing.
A solid-state drive (SSD) is offline as a result of a drive hardware error.
A solid-state drive (SSD) is reporting a predictive failure analysis (PFA).
A solid-state drive (SSD) is reporting too many errors.
An unrecognized SAS device.
SAS error counts exceeded the warning thresholds.
SAS errors exceeded critical thresholds.
A solid-state drive (SSD) initialization failed.
A solid-state drive (SSD) is offline due to excessive errors.
A solid-state drive (SSD) exceeded the warning temperature threshold.
A solid-state drive (SSD) exceeded the offline temperature threshold.
Error
code
1200
1200
1200
1320
1330
1335
1625
1360
1370
1623
1625
1624
1695
1570
1627
1627
1627
1627
1627
1201
1202
1205
1215
1215
1665
1216
1216
1661
1311
1218
1217

Advertisement