IBM Storwize V7000 Troubleshooting And Maintenance Manual page 88

Table of Contents

Advertisement

Table 19. Event IDs and codes (continued)
Notification
Event ID
type
045004
E
045005
W
045006
E
045007
E
045008
E
045009
E
045010
E
045011
E
045012
W
045013
W
045014
E
045015
E
045016
E
045017
E
045018
E
045019
E
045020
W
045021
E
045022
E
045023
E
045024
E
045025
E
045026
E
045027
E
045028
E
045029
E
045031
E
045033
E
045034
E
045035
E
045036
E
045037
E
045038
E
045040
E
045041
E
045042
W
045044
W
045045
W
72
Storwize V7000 Version 6.1.0: Troubleshooting, Recovery, and Maintenance Guide
Condition
The power supply unit is not installed.
The power supply unit has indicated an input power failure.
The power supply unit has indicated a dc failure.
The power supply unit has failed.
There is no communication with the power supply unit.
The model type for this enclosure is not valid.
The power supply unit type is unknown to this product.
The power supply unit serial number is not valid.
The canister temperature is at the warning level.
The canister temperature is at the critical level.
The SAS cable was excluded because of a missing device.
A SAS cable was excluded because too many change events were caused. 1260
A SAS cable was excluded.
A SAS cable is operating at a reduced speed.
A SAS cable was excluded because frames were dropped.
A SAS cable was excluded because the enclosure discovery timed out.
A SAS cable is not present.
A canister was removed from the system.
A canister has been in a degraded state for too long and cannot be
recovered.
A canister is encountering communication problems.
The canister VPD is not valid.
The canister has experienced too many resets.
The drive slot is causing the network to be unstable.
The drive slot is not running at 6 Gbps
The drive slot is dropping frames.
The drive is visible through only one SAS port.
The drive power control is not functional.
The drive slot contains a device that is not responding to queries.
The managed enclosure is not visible from any node canisters.
The electronics in the enclosure has failed.
The electronics in the enclosure has experienced a critical failure.
The SAS network has too many errors.
The SAS network has too many errors.
The firmware update for the enclosure component has failed.
More than one initiator ports were detected on the same strand.
The order of the enclosures is different on each strand.
Multiple canisters are connected to a single canister port.
Canister 1 is connected to canister 2.
Error
code
1128
1138
1126
1124
1148
1124
1124
1124
1098
1095
1260
1255
1260
1260
1260
1265
1036
1034
1038
1032
1032
1686
1686
1686
1686
1008
1685
1042
1694
1008
1048
1048
3015
1005
1005
1005
1005

Advertisement