Configuration events are generated when configuration parameters are set. Configuration events are
recorded in a separate log. Configuration events are not notified through email, SNMP, or syslog.
Informational event codes
The informational event codes provide information on the status of an operation.
Informational events are recorded in the event log and, depending on the configuration, can be notified
through email, SNMP, or syslog.
Informational event codes can be either notification type I (information) or notification type W (warning).
An informational event report of type (W) might require user attention. Table 18 provides a list of
informational event codes, the notification type, and the meaning of the event code.
Table 18. Informational event codes
Event code
980221
980230
980231
980310
980349
980352
980371
980372
980380
980381
980435
980440
980446
980501
980502
980503
980504
981002
981003
981004
981007
981014
4 4 4
981015
4
981020
981022
981025
66
Storwize V7000 Version 6.1.0: Troubleshooting, Recovery, and Maintenance Guide
Notification type
Description
I
The error log is cleared.
I
The SSH key was discarded for the service login user.
I
User name has changed.
I
A degraded or offline managed disk group is now online.
I
A node has been successfully added to the cluster.
I
Attempt to automatically recover offline node starting.
I
One node in the I/O group is unavailable.
W
Both nodes in the I/O group are unavailable.
I
Maintenance mode was started.
I
Maintenance mode has ended.
W
Failed to obtain directory listing from remote node.
W
Failed to transfer file from remote node.
I
The secure delete is complete.
W
The virtualization amount is close to the limit that is licensed.
W
The FlashCopy feature is close to the limit that is licensed.
W
The Metro Mirror or Global Mirror feature is close to the limit that is
licensed.
I
The limit was reached for the external virtualization feature.
I
Fibre-channel discovery occurred; configuration changes are
required.
I
Fibre-channel discovery occurred; configuration changes are
complete.
I
Fibre-channel discovery occurred; no configuration changes were
detected.
W
The managed disk is not on the preferred path.
W
The LUN discovery has failed. The cluster has a connection to a
device through this node but this node cannot discover the
unmanaged or managed disk that is associated with this LUN.
W
The LUN capacity equals or exceeds the maximum. Only part of the
disk can be accessed.
W
The managed disk error count warning threshold has been met.