Required I/O Address Space - Siemens SIMATIC ET 200SP Manual

Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

Configuring

5.3 Required I/O address space

Channel "Parameter" group
Time lag
Dithering
Dither ramp up time
Dither ramp down time
Dither amplitude
Dither period
High speed output is not available for the one channel (4 A) configuration that uses a parallel connection of the two (2 A)
1
channels.
In PWM mode, you can enable either High-speed or Current control, but not both options at once.
2
Parameter is disabled in isochronous mode.
3
Parameter is disabled when current control is active
4
5.3
Required I/O address space
Address space of the technology module
Table 5- 3
TM Pulse 2x24V I/O address space usage
Function
Program control of module operation
Feedback module status to control
program
Additional information
A description on how to use the control and feedback interface of TM Pulse 2x24V can be
found in the chapter Program control and feedback interface (Page 110).
100
Pulse output
PWM
mode
mode
Bytes per channel
12 output bytes (Q addresses)
8 input bytes (I addresses)
Pulse train
On/Off delay
mode
mode
Total I/O bytes
Single channel (4 A)
12 output bytes
8 input bytes
Technology module TM Pulse 2x24V (6ES7138‑6DB00‑0BB1)
Frequency
DC motor
output
mode
mode
Total I/O bytes
Dual channel (2 A)
24 output bytes
16 input bytes
Manual, 09/2015, A5E35061186-AA