Pulse output parameters
Pulse output parameter
Mode
High-speed output
1
Function DI
Input delay
On-delay
Only if the module is configured as "2 channels (2 A)"
1
Technology module TM Pulse 2x24V (6ES7138‑6DB00‑0BB1)
Manual, 09/2015, A5E35061186-AA
Meaning
0 = Set the Pulse output operating mode.
The output supports higher frequencies at small-
er loads when enabled.
You can use the DIn.0 digital input as an input or
as a hardware enable. The signal at DIn.0 is
interpreted by the TM Pulse 2x24V, after noise
filtering by the input delay, as the start of the
output sequence.
DIn.0: a digital input must be stable over the
delay time (signal noise suppression).
The time from the start of the output sequence to
the output of the pulse. You can change the
On-delay in your control program using the SLOT
parameter.
Modes and Functions
3.2 Pulse output (single pulse) mode
Value Range
0 = Pulse output
1 = Pulse width modulation
2 = Pulse train
3 = On/Off-delay
4 = Frequency output
5 = DC Motor
0 = Disabled
1 = Enabled
0 = Input
1 = HW enable
0 = Off (4 μs)
1 = 0.05 ms
2 = 0.1 ms
3 = 0.4 ms
4 = 0.8 ms
5 = 1.6 ms
6 = 3.2 ms
7 = 12.8 ms
8 = 20 ms
0 μs to 85,000,000 μs
Default
1
Disabled
Input
0.1 ms
0 μs
21