Metering Tone Parameters - AudioCodes Mediant 2000 User Manual

Voip media gateway
Hide thumbs Also See for Mediant 2000:
Table of Contents

Advertisement

User's Manual
45.11.9.3

Metering Tone Parameters

The metering tone parameters are described in the table below.
Parameter
Web: Generate
Metering Tones
EMS: Metering Mode
[PayPhoneMeteringMo
de]
Charge Codes Table
[ChargeCode]
Version 6.6
Metering Tone Parameters
Determines the method used to configure the metering tones that are
generated to the Tel side.
[0] Disable = (Default) Metering tones aren't generated.
[1] Internal Table = Metering tones are generated according to the
device's Charge Code table (using the ChargeCode parameter).
Notes:
This parameter is applicable only to ISDN Euro trunks for sending
AOC Facility messages (see Advice of Charge Services for Euro
ISDN on page 353).
If you select 'Internal Table', you must configure the Charge Codes
table, using the ChargeCode parameter.
This table parameter configures metering tones and their time intervals
that the E1 trunk (EuroISDN) sends in AOC Facility messages to the
PSTN (i.e., PBX).
The format of this parameter is as follows:
[ChargeCode]
FORMAT ChargeCode_Index = ChargeCode_EndTime1,
ChargeCode_PulseInterval1, ChargeCode_PulsesOnAnswer1,
ChargeCode_EndTime2, ChargeCode_PulseInterval2,
ChargeCode_PulsesOnAnswer2, ChargeCode_EndTime3,
ChargeCode_PulseInterval3, ChargeCode_PulsesOnAnswer3,
ChargeCode_EndTime4, ChargeCode_PulseInterval4,
ChargeCode_PulsesOnAnswer4;
[\ChargeCode]
Where,
EndTime = Period (1 - 4) end time.
PulseInterval = Period (1 - 4) pulse interval.
PulsesOnAnswer = Period (1 - 4) pulses on answer.
For example:
ChargeCode 1 = 7,30,1,14,20,2,20,15,1,0,60,1;
ChargeCode 2 = 5,60,1,14,20,1,0,60,1;
ChargeCode 3 = 0,60,1;
ChargeCode 0 = 6, 3, 1, 12, 2, 1, 18, 5, 2, 0, 2, 1;
Note: To associate a configured Charge Code to an outgoing Tel-to-IP
call, use the Outbound IP Routing Table.