Configuring Internal Clock As Clock Source; Configuring Cas State Machines - AudioCodes Mediant 2000 User Manual

Voip media gateway
Hide thumbs Also See for Mediant 2000:
Table of Contents

Advertisement

User's Manual

21.2.2.2 Configuring Internal Clock as Clock Source

This section describes how to configure the device to use its internal clock source. The
internal clock source is a stratum 4E-compliant clock source. When the device has no line
interfaces, the device should be configured in this mode.
To configure internal clock as clock source:
1.
Set the clock source to be from the device's internal oscillator. In the TDM Bus
Settings page, set the 'TDM Bus Clock Source' parameter (TDMBusClockSource) to
Internal.
2.
Set the line to drive the clock on all trunks: In the Trunk Settings page, set the 'Clock
Master' parameter (ClockMaster) to Generated (for all trunks).
21.3

Configuring CAS State Machines

The CAS State Machine page allows you to modify various timers and other basic
parameters to define the initialization of the CAS state machine without changing the state
machine itself (no compilation is required). The change doesn't affect the state machine
itself, but rather the configuration.
The CAS table used can be chosen in two ways (using the parameter CasChannelIndex):
Single CAS table per trunk
Different CAS table per group of B-channels in a trunk
To modify the CAS state machine parameters:
1.
Open the CAS State Machine page (Configuration tab > VoIP menu > PSTN
submenu > CAS State Machines).
2.
Ensure that the trunk is inactive. The trunk number displayed in the 'Related Trunks'
field must be green. If it is red, indicating that the trunk is active, click the trunk number
to open the Trunk Settings page (see 'Configuring Trunk Settings' on page 261),
select the required Trunk number icon, and then click Stop Trunk.
3.
In the CAS State Machine page, modify the required parameters according to the
table below.
4.
Once you have completed the configuration, activate the trunk if required in the Trunk
Settings page, by clicking the trunk number in the 'Related Trunks' field, and in the
Trunk Settings page, select the required Trunk number icon, and then click Apply
Trunk Settings.
5.
Click Submit, and then reset the device (see 'Resetting the Device' on page 393).
Version 6.6
Figure 21-4: CAS State Machine Page
265
21. Digital PSTN
Mediant 2000

Advertisement

Table of Contents
loading

Table of Contents