P0680 - Logical Status - WEG CFW-11 Communications Manual

Hide thumbs Also See for CFW-11:
Table of Contents

Advertisement

0 = Off
1 = Ramp Stop
2 = General Disable
3 = Change to LOCAL
4 = Change to LOCAL
5 = Fault Trip
For the CAN interface being used with the CANopen protocol, the following events are considered communication
errors:
A133 alarm/fault F233: CAN interface without power supply.
A134 alarm/fault F234:
A135 alarm/fault F235: CANopen communication error (
The description of those alarms/faults is found in the section 7.
The actions described in this parameter are executed by means of the automatic writing of the respective bits on the
control via CAN parameter – P0684. In order to be effective, it is necessary that the inverter be programmed to be
controlled via CAN interface. This programming is done by means of parameters P0220 to P0228.
P0680 – Logical Status
Range:
0000h – FFFFh
Proprieties:
RO
Access groups via HMI:
01 PARAMETER GROUPS
∟ 49 Communication
∟ 111
Status/Commands.
Description:
It allows the monitoring of the inverter status. Each bit represents one state:
Bits
15
14
Function
Table 3.1 - Values for parameter P0313
Options
No action is taken and the inverter remains in the
existing status.
A stop command with deceleration ramp is executed
and the motor stops according to the programmed
deceleration ramp.
The inverter is disabled by removing the General
Enabling and the motor coasts to stop.
The inverter commands change to LOCAL.
The inverter is changed to the local mode; However,
keeping the
the enabling and reference commands received via the
commands and the
network , in case the inverter had been programmed
reference
for start/stop via HMI or 3-wire and reference via HMI
or electronic potentiometer, are kept in the local mode.
Instead of an alarm, a communication error causes a
fault at the inverter, so that it becomes necessary to
perform the inverter fault reset in order to get it back to
normal operation.
bus off.
.
13
12
11
10
Description
Node Guarding
9
8
7
6
)
Default:
-
5
4 to 0

Advertisement

Table of Contents
loading