4 PARAMETERS

4.1 COMMANDS AND COMMUNICATION STATUS

See below the parameters related to the states and commands through the communication networks available for
the frequency inverter.
P680 - Logical Status
Adjustable
0 to FFFF (hexa)
Range:
Bit 0 = Reserved
Bit 1 = Run Command
Bit 2 = Fire Mode
Bit 3 to 4 = Reserved
Bit 5 = 2nd Ramp
Bit 6 = Config. Mode
Bit 7 = Alarm
Bit 8 = Running
Bit 9 = Enabled
Bit 10 = Forward
Bit 11 = JOG
Bit 12 = Remote
Bit 13 = Subvoltage
Bit 14 = Reserved
Bit 15 = Fault
Properties:
ro
Description:
The inverter status word is unique for all the sources and can only be accessed for reading. It indicates all the
relevant operating status and modes of the inverter. The function of each bit of P680 is described in
page
13.
PARAMETERS
Factory
-
Setting:
Table 4.1 on