Remove the 5 V interlock switch cable from the restraint (S) on the backside of the EP drive.
16.
Remove the EP drive.
17.
Installation notes:
The EP drive assembly for the single-function printers and the multiple-function printers (MFP) are the same,
except for the fuser retract link. The package comes with the EP drive assembly with the single-function printer
link installed. To set up the EP drive for the multiple-function printer (MFP), exchange the links.
To change the fuser retract link:
1.
Remove the E-clip (A) and the follower cam.
Remove the fuser retract link (B), and discard.
2.
S
7526
Repair information