Appendix B Modification For Selectable Sampling - Honeywell AutoSet 1500 User Manual

Wintriss two-channel load analyzer
Table of Contents

Advertisement

Appendix B
Modification for Selectable Sampling
For those AutoSet 1500 load monitors which include custom selectable sampling, the
stroke sample length can be set to 1, 15, 30 or 60 strokes.
Dip switches 1 and 4 on switch block S1 are used to make the settings. On the standard
AutoSet, dip switch 4 is not used.
Figure B-1. Stroke select switch (S1) with on-off positions for switch 4 shown
The following chart shows how to set dip switches 1 and 4 for 1, 15, 30 or 60 stroke
settings:
To set sample to
1 stroke
15 strokes
30 strokes
60 strokes
AutoSet 1500 User Manual
set stroke select #1 to:
1 stroke
15 strokes
15 strokes
1 stroke
53
set switch #4 to:
ON
ON
OFF
OFF
App B
1088500

Advertisement

Table of Contents
loading