Honeywell AutoSet 1500 User Manual page 43

Wintriss two-channel load analyzer
Table of Contents

Advertisement

NOTE : Changing this switch shuts off the decimal point. Tonnage will only
be displayed in whole numbers.
When full scale tonnage is more than 1500 tons
Leave out the least significant digit when setting the switches. For instance,
2000 would be set as "2", "0", "0"—the same as if you were setting full scale
tonnage to 200 tons. For presses over 1500 tons, you must multiply all readings
by 10. For instance, 155 tons would be displayed as 15.5 tons. 1500 tons would
be displayed as 150 tons.
NOTE: Make sure the decimal point switch (No. 3 on S6) is set to the "on"
position. See Figure 3–5. If not set to "on", push switch all the way to the left
with a pen or your thumbnail.
4.
Turn power to AutoSet off, then back on. This must be done to reset the unit after
changing the tonnage switches. (Also resets decimal point if decimal point switch
was changed.)
AutoSet 1500 User Manual
Figure 3-6. Switch block S6 showing decimal point switch
36
Calibration
Ch 3
1088500

Advertisement

Table of Contents
loading

Table of Contents