Event Tables - Aastra Ascotel IntelliGate 150 System Manual

Hide thumbs Also See for Ascotel IntelliGate 150:
Table of Contents

Advertisement

Ascotel® IntelliGate® 150/300 as of I7.9
Event/ error message
User does not answer
Wake-up call unanswered
Wrong or missing wiring
adapter
6. 6. 1. 2

Event tables

Event tables list all the event messages the PBX is capable of generating (see
Tab.
96).
The frequency of event messages can range between "0" and "20".
The time period is indicated in hours, ranging between "0" and "672". The longest
time period "672" corresponds to 28 days or 4 weeks.
If the frequency of event messages is set to "0", the time period will also automati-
cally be set to "0". No event message is sent to a signal destination.
If the frequency of event messages is set to "1", the time period will automatically
be set to "0".
The event message will immediately be sent to the signal destinations.
If the time period is set to "0" hours, the frequency of the event message will auto-
matically be set to "1".
The event message will immediately be sent to the signal destinations.
There are 4 event tables in the Fault & Maintenance Manager. Each event table can
be individually configured and allocated to one of the 4 signal destinations. This
means it is possible to decide which event message – if any – should be sent to a
particular signal destination either immediately, with a delay or not at all.
Example
Tab. 97
Example of event table
Event type
Total Synchronization loss
System Overload
No response from network
In this example an event message is sent to the message destinations if there is a
"Total synchronization
sage 10 times within 1 hour. With the event
196
Trigger condition
No answer to incoming DDI call from user on S
bus or AD2
Room wake-up call not answered
There is no wiring adapter in the wiring
adapter slot or the wiring adapter fitted is
unsuitable.
Frequency
10
1
0
loss" event message when the PBX generates the event mes-
Details
DDI No., date, time
Room No., date, time
Slot number, date, time
Time period
1
0
0
type"System
overload", an event mes-
Operation and Maintenance

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ascotel intelligate 300

Table of Contents