X424: Power Supply For Digital Inputs/Outputs; Table 3-7 Terminal Block X424 - Siemens SINAMICS S120 Equipment Manual

Control units and additional system components
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Additional System Components
3.2 Option Board: Terminal Board 30 (TB30)
3.2.3.4

X424: Power supply for digital inputs/outputs

Table 3-7
Terminal block X424
Terminal
+
+
M
M
Max. connectable cross-section: 2.5 mm
Type: Screw terminal 2 (see Appendix A)
Note
The two "+" and "M" terminals are jumpered in the connector and not in the unit. This
ensures the supply voltage is looped through.
This power supply is required for the digital inputs/outputs only. The electronics power
supply and the power supply for the analog inputs/outputs are drawn via the option slot of
the Control Unit.
Note
The power supply of the digital inputs/outputs and the electronics power supply of the
Control Unit are isolated.
Note
If a momentary interruption in the voltage occurs in the 24 V supply, the digital outputs will
be deactivated until the interruption has been rectified.
3-10
Function
Power supply
Reserved, do not use
Ground
Ground
2
Technical specifications
Voltage: 24 V DC (20.4 V – 28.8 V)
Current consumption: max. 4 A (per digital output max. 0.5 A)
Max. current via jumper in connector:
20 A at 55° C
Equipment Manual Control Units and Additional System Components
Equipment Manual, (GH1), 12/2004 Edition, 6SL3097-2AH00-0BP1