Encoder System Connection
4.5 Sensor Module Cabinet 30 (SMC30)
4.5.3.3

X520 sensor connection 1 TTL with open-circuit monitoring

Table 4-16
Sensor connection X520
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Caution
The sensor power supply can be parameterized to 5 V or 24 V. The sensor may be
destroyed if you enter the wrong parameters.
4-24
Signal name
Reserved, do not use
Reserved, do not use
Reserved, do not use
P_Encoder 5 V / 24 V
P_Encoder 5 V / 24 V
P_Sense
M_Encoder (M)
Reserved, do not use
M_Sense
R
R*
B*
B
A*
A
Technical specifications
Sensor power supply
Sense input sensor power supply
Ground for sensor power supply
Ground sense input
Reference signal R
Inverted reference signal R
Inverted incremental signal B
Incremental signal B
Inverted incremental signal A
Incremental signal A