Supplementary system components
6.3 TB30 terminal board
6.3.3.3

Power supply of digital outputs

Table 6- 3
Terminal block X424
Terminal
+
+
M
M
Table 6- 4
X424 wiring
Characteristics
Connectable cable types and conductor cross-sections
Rigid, flexible
with wire-end ferrule without plastic sleeve:
with wire-end ferrule and with plastic sleeve:
Stripped length
Tool
Tightening torque
Characteristics
Two "+" terminals and two "M" terminals are available. These are jumpered in the connector.
This loops through the power supply.
This power supply is only required for the digital outputs.
The option slot of the D4x5-2 control unit also provides the following power supplies:
● Electronic power supply of the TB30
● Supply of the analog inputs and outputs
The power supply of the digital outputs and the electronics power supply of the control unit
are isolated.
88
Function
Power supply
Power supply
Ground
Ground
Technical specifications
Voltage: 24 VDC (20.4 V – 28.8 V)
Max. power consumption: 4 A
Max. power consumption per digital output: 0.5 A
Max. current via bridges in the connector: 20 A
Type
0.08 mm
to 2.5 mm
2
2
0.5 mm
to 2.5 mm
2
2
0.5 mm
to 1.5 mm
2
2
7 mm
Screwdriver 0.6 x 3.5 m
0.5 to 0.6 Nm
SIMOTION D4x5-2