4.5.6

Electrical connection

Shield contacts are only required if the system is connected to X521/X531.
Shield contact for the SMC30 from Weidmüller
Figure 4-14
Shield contacts for the SMC30
Weidmüller:
The bending radii of the cables must be taken into account (see description of
MOTION-CONNECT).
4.5.7

Technical specifications

Electronics power supply
Voltage
Current
Max. ambient temperature up to an
altitude of 2000 m
Note:
As of an altitude of 2000 m, the max. ambient temperature decreases by 7° C every 1000 m.
PE/ground connection
Weight
Equipment Manual Control Units and Additional System Components
Equipment Manual, (GH1), 12/2004 Edition, 6SL3097-2AH00-0BP1
Unit
V
DC
A
DC
° C
On housing with M4/1.8 Nm screw
kg
Encoder System Connection
4.5 Sensor Module Cabinet 30 (SMC30)
Value
24 DC (20.4 – 28.8)
max. 0.6
55
0.8
4-29