Note !b
Command Syntax:
where:
<state-low value 5
c state-high-value >
<label-name >
Examples:
Query Syntax:
Returned
Format:
Example:
HP 1650B/HP 1651B
Programming Reference
The HAXis command allows you to select whether states or a label's
values will be plotted on the horizontal axis of the chart. The axis is scaled
by specifying the high and low values.
The shortform for STATES is STA. This is an intentional deviation from
the normal truncation rule.
The HAXis query returns the current horizontal axis label and scaling.
c label-name > , -z label-low-value 5, -z label-high-value > )
:: = integer from -1023 to 1024
:: = integer from <state-low-value > to + 1024
:: = a string of up to 6 alphanumeric characters
:: = string from 0 to 2%-l (#HFFFFFFFF)
:: = string from c label-low-value > to 23'-1 (#HFFFFFFFF)
OUTPUT XXX;":MACHINEl:SCHART:HAXIS
OUTPUT XXX;":MACHINEl:SCHART:HAXIS
[ M A C H i n e { 1 12):SCHat-t:
H A X i s ] {STAtes, c state-low-value >, -z state-high-value > 1
10 DIM String$[lOO]
20 OUTPUT XXX;":MACHINEl:SCHART:HAXIS?"
30 ENTER XXX;
50 END
command/query
STATES, -100, 100"
'DATA', l-511', '511"'
HAXis