Command Syntax:
where:
c l a b e l - n a m e >
Example:
HP 1650B/HP 16518
Programming Reference
The PATTern command allows you to construct a pattern recognizer
term for the timing analyzer trigger on a per label basis. Each command
deals with only one label in the given pattern; therefore, a complete timing
trace specification could require several commands. Since a label can
contain up to 32 bits, the range of the pattern value will be between 0 and
hexadecimal (#H) or decimal (default). When the value of a pattern is
expressed in binary, it represents the bit values for the label inside the
pattern recognizer term. Since a pattern value can contain don't cares,
the pattern specification parameter is handled as a string of characters
instead of a number.
The PAlTern query returns the pattern specification for the specified
label in the base previously defined for the label.
1 IP}:TTRace: PAllern
:: = string of up to 6 alphanumeric characters
:: = "{#B{OI 1 IX} . . * 1
OUTPUT XXX; ":MACHINEl:TTRACE:PATTERN
command/query
c label-name >, e pattern-spec >
. . I
. }"
' D A T A ' , ' 2 5 5 " '