MAINTENANCE AND REPAIR
SECTION 6
Figure
6-6.
CRT mounting bolts and high voltage connector.
11.
Face the screen and carefully pull the CRT with the yoke assembly
toward you.
WARNING 1:
DO NOT STRIKE OR SCRATCH OR USE MORE THAN MODERATE
PRESSURE WHEN HANDLING THE CRT.
WARNING
-2:
STRESS IN THE CRT NECK CAN BREAK THE CRT AND CAUSE
SERIOUS PERSONAL INJURY.
HOLD THE CRT BY THE RIM
OF THE FACE, NEVER BY THE NECK.
YOU MAY GENTLY
SUPPORT THE NECK, BUT ONLY TO STEADY AND GUIDE THE
CRT.
12.
Place the CRT face down on a soft grit-free surface.
13.
Loosen the yoke-mounting screw (refer to Figure 7-14 in Section 7)
and pull the yoke straight up and off the CRT neck.
WARNING:
NEVER PRY THE YOKE OFF THE CRT NECK.
TO DO SO MAY
SCRATCH OR BREAK THE CRT.
14.
To replace the CRT, install the deflection yoke and repeat steps
1 through 11 in reverse.
NOTE 1:
Replace the CRT so that the anode button is on the right
side as viewed from the front of the terminal.
NOTE 2:
Make sure the CRT adjustments are correctly set (refer to
Section 7).