At The Ground Controls; Test Emergency Stop; Test The Up/Down Functions - Genie GS-1930 Operator's Manual

Scissor lift
Hide thumbs Also See for GS-1930:
Table of Contents

Advertisement

Sixth Edition • Ninth Printing

At the Ground Controls

1
Select a test area that is firm, level and free of
obstruction.
2
Be sure the batteries are connected.
3
Pull out the platform and ground red
Emergency Stop button to the on position.
4
Turn the key switch to ground control.
5
Observe the diagnostic LED readout on the
platform controls.
Result: The LED should look like the picture
below.
6
Observe the diagnostic LCD readout on the
ground controls.
Result: The LCD should display the model and
hour meter.
Part No. T107026

Test Emergency Stop

7
Push in the ground red Emergency Stop
button to the off position.
Result: No functions should operate.
8
Pull out the red Emergency Stop button to the
on position.

Test the Up/Down Functions

The audible warnings on this machine and the
standard horn all come from the same central
alarm. The horn is a constant tone. The descent
alarm sounds at 60 beeps per minute. The alarm
sounds at 180 beeps per minute when the pothole
guards have not deployed and when the machine
is not level. An optional automotive-style horn is
also available.
9
Do not press the lift function enable button.
10 Press the platform up or platform down button.
Result: The lift function should not operate.
11 Do not press the platform up or platform down
buttons.
12 Press the lift function enable button.
Result: The lift function should not operate.
13 Press and hold the lift function enable button,
and press the platform up button.
Result: The platform should raise.
14 Press and hold the lift function enable button,
and press the platform down button.
Result: The platform should lower. The
descent alarm should sound while the platform
is lowering.
GS-30 • GS-32 • GS-46 • GS-47
Operator's Manual
Inspections
31