Adtec RD-71 User Manual page 48

10-bit 1080p integrated receiver decoder
Hide thumbs Also See for RD-71:
Table of Contents

Advertisement

selected, the tuner/demodulator will determine the actual modulation type.
Symbol Rate Mode​ - ​
S ymbol Rate is defined for digital communications as the number of
symbols per second. The amount of data per symbol depends on the modulation type and
FEC code rate. Units for this field are expressed in MSym/s and the actual range is
determined by feature key. If zero [0] or AUTO is entered, the tuner/demodulator will
determine the actual symbol rate.
ISI​ - ​
I SI (input stream identifier) is required for multistream applications. If a multistream
RF source is detected, BBHeaders containing this value will be demodulated and output to
the receiver. This value has no effect during single stream applications.
PLS Mode​ - PLS Mode determines the Gold sequence code to use for descrambling.
DEFAULT (or 0), CODE1 (User entered sequence in 'PLS Code 1') or CODE2 (User entered
sequence in 'PLS Code 2')
PLS Code 1​ - User defined PLS Gold sequence code, active when PLS Mode set to 'CODE1'.
PLS Code 2​ - User defined PLS Gold sequence code, active when PLS Mode set to 'CODE2'.
RF Params (PRX model)
48

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents