Taylor-Dunn B0-248-36 Operation, T Roubleshooting And Replacement Parts Manual page 198

Equipped with gt-drive system
Hide thumbs Also See for B0-248-36:
Table of Contents

Advertisement

Electrical Troubleshooting
TESTING THE CHARGING CYCLE
In typical installations, The charge cycle will be completed in 8 to 12 hours depending on the state of
charge of the batteries when the charge cycle was started.
NOTE: The charge cycle time is limited to 20-hours (max). A fault will occur if charging time exceeds the time
limit. Refer to the fault code table for more information.
A charger could remain on for longer than 12 hours if:
• The vehicle is equipped with batteries larger than 220 Amp hour capacity.
• The charging cycle is interrupted at any time during the charging cycle.
• Defective batteries causing a fluctuating DC voltage that confuses the charger.
• One or more defective cells in the battery pack.
• A brownout (drop in AC line voltage) during the charging cycle.
• An electrically noisy charging environment.
NOTE: This charger has a maintenance mode that will restart the charger if the battery voltage drops below a
threshold after the charge cycle is complete. In some cases, it may appear that the charger is not turning off due to
that the charger has restarted. Fully test the battery pack before assuming that the charger is not turning off or
running too long.
A charger could turn off in less than 12 hours, but still show symptoms of overcharging if:
• The electrolyte in the batteries is too high (boil over).
• The electrolyte in the batteries is too low (excessive gassing or sulfur smell).
To test the charger to see if it is turning off correctly, monitor the battery voltage and charging current during
the charging cycle as indicated below.
Using a digital voltmeter and clamp on DC ammeter, monitor the battery voltage and current during the
charging cycle. The charging current should remain within 10% of the DC output current (see previous
page) until the battery voltage reaches V1. When the voltage reaches V1, the charging current will drop
significantly and slowly taper off (voltage will remain constant). The charger should turn off within 2 to 4
hours after entering the second stage when the charginc current is down to A1.
GEL batteries must be charged with a charger configured for
GEL batteries. Use of any other charger will result in damage
to the batteries and premature failure of the batteries.
Signet Charger Troubleshooting
Page 4
R

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents