Level 1 Faults
Fault Code
Description
F01000
P/S Motor Overheated
F01001
Motor Brush Fault
F01002
Pump Motor Brush Fault
F01003
P/S motor Brush Fault
F01004
Low Battery Volts
F01005
Controller Overheated
F01006
Traction Motor Hot
F01007
Pump Motor Overheated Stop the vehicle and allow
F01008
Wiring fault
Level 4 Faults
Fault Code
Description
F04000
Open Contactor
F04001
Contactor Welded
F04002
Steer POT Fault
F04003
Sequence Fault
F04004
F&R Fault
F04005
F&R Fault
F04006
Interlock Fault
F04007
Inch Switch Fault
F04008
Steer Fault
F04009
Low Battery Volts
F04010
High battery Volts
F04011
Out of Range Fault
F04012
CRC Fault
F04013
Capacitor Fault
Safety Rules
Page 14

Fault Code Tables

What to do
Stop the vehicle and allow
the system to cool down.
Refer to service technician
Refer to service technician
Refer to service technician
Batteries are empty and
require charging. If this
fault does not reset after the
charge cycle is complete
then there may be a
problem with the charger or
batteries.
Refer to qualified service
technician.
Stop the vehicle and allow
the system to cool. This
could be a result of an
overloaded vehicle.
Stop the vehicle and allow
the system to cool down.
This could be a result of an
overloaded vehicle
the system to cool down.
Refer to service technician
What to do
Refer to service technician
Refer to service technician
N/A
Start up switches were not
operated in the correct
order. Refer to Vehicle
Operation Guidelines for
correct sequence.
Refer to service technician
Direction was selected
before start switch was
closed. Place direction
selector in the OFF position
and restart.
Seat or foot interlock switch
not closed.
F&R switch NOT in neutral.
Refer to service technician
Extreme low battery voltage
at the controller. May be a
result of severely
discharged battery or
wrong battery installed.
Confirm that the correct
battery is installed and
charge the battery.
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Level 5 Faults
Fault Code
Description
F05000
Contactor Over Current
F05001
Controller Fault
F05002
Configuration Error
F05003
Internal Fault
F05004
VA Fail
F05005
Data Layer Fault
F05006
MOSFET Short
F05007
Power Up Fault
F05008
Line Contactor Short
F05009
Wiring/Motor Short
F05010
Power Up Fault
F05011
Drive 0 ON
F05012
Drive 1 ON
F05013
Drive 0 OFF
F05014
Drive 1 OFF
F05015
Drv 0 MOSFET Trip
F05016
Drv 1 MOSFET Trip
F05017
Traction ON
F05018
Traction OFF
F05019
MOSFET Short_L
F05020
Power Up Fault
F05021
Traction Welded
F05022
Traction MOSFET
F05023
Auto Zero
F05024
Drive 0 ON L
F05025
Drive 1 ON L
F05026
Drive 0 OFF L
F05027
Drive 1 OFF L
F05028
0 MOSFET trip L
F05029
1 MOSFET trip L
F05030
Traction ON L
F05031
Traction OFF L
F05032
MOSFET Short R
F05033
Power Up Fault
F05034
Traction Welded
F05035
Traction MOSFET
F05036
Auto Zero R
F05037
Drive 0 ON R
F05038
Drive 1 On R
F05039
Drive 0 OFF R
F05040
Drive 1 OFF R
F05041
0 MOSFET Trip R
F05042
1 MOSFET Trip R
F05043
Traction ON R
F05044
Traction OFF R
F05045
Stack Corrupt
F05046
Open Contactor
Level 2 Faults
Fault Code
Description
F02000
Throttle Fault
F02001
Throttle Fault
F02002
Belly Switch Fault
F02003
Open Field
F02004
Open Field L
F02005
Open Field R
What to do
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician
What to do
Occurs if throttle control
voltage is high at start
up indicating that the
throttle pedal was
depressed when the
start switch was closed.
If the pedal was not
depressed, then refer to
qualified service
technician.
Refer to service technician
Refer to service technician
Refer to service technician
Refer to service technician