Taylor-Dunn B0-248-48AC Operation, T Roubleshooting And Replacement Parts Manual page 27

Equipped with ac motor peed control
Table of Contents

Advertisement

SAFETY RULES AND OPERATING INSTRUCTIONS
Model # B 2-48 / B 2-54 equipped with 30:1 drive ratio
Aceleration Parameters (normal mode)
Function
Value
FwdAS LS
2.6
FwdAc HS
4.0
RevAc LS
8.0
RevAc HS
7.0
Aceleration Parameters (low speed mode)
FwdAS LS
4.0
FwdAc HS
5.5
RevAc LS
8.0
RevAc HS
7.0
Deceleration Settings
Brake Multplier
40
Normal Decl HS
8.0
Normal Decl LS
10.0
Tow Decl HS
8.5
Tow Decl LS
8.0
Maintenance Meter Function
Service Timer
0*
Speed Limits
Max (see warning)
6,250
Tow (optional)
60
Rev
45
Low Batt
40
Service Due
20
Batery Characteristics
Full Volts
2.165
Empty Volts
1.730
BDI Level for Batt Spd
15
BDI Reset %
80
Reset Volts
2.1
Discharge Time
60
Miscellaneous
SRO Min Speed
3,000
Unit
Description
Time to accelerate to ~15% of full
S
speed
S
Time to accelerate to full speed
Time to accelerate to from FwdAC LS
S
to full
S
Time to accelerate to full speed
Time to accelerate to ~15% of full
S
speed
S
Time to accelerate to full speed
Time to accelerate to from FwdAC LS
S
to full
S
Time to accelerate to full speed
Brake regen multiplier is activated by
%
the brake switch
Time to decelerate to 0 when above
S
20% of full speed
Time to decelerate when below 20%
S
of full speed
Time to decelerate to 0 when above
S
20% of full speed
Time to decelerate when below 20%
S
of full speed
Refer to Maintenance Meter
H
supplementary manual
RPM
Governed speed (see formula)
Percentage of Max speed when Tow
%
Switch is ON
Percentage of Max speed when in
%
reverse
Percentage of Max speed when low
%
battery warning is ON
Percentage of Max speed when
%
service is due. See maintenance Meter
Function
Battery must exceed this voltage to be
V
considered fully charged
V
Voltage of a fully discharged battery
Low battery warning is ON when
%
battery is discharged below this level
Battery must be discharged below this
%
value before the BDI will be allowed
to reset
Battery voltage must be above this
V
value to reset the BDI. Modified by
the 'BDI Reset %' above)
M
Estimated battery discharge rate
Motor must be below this RPM to
RPM
change directions with the throttle
pedal depressed
Safety Rules
Page 13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B0-254-48acB 2-48B 2-54

Table of Contents