Clamp On Dc Ammeter To Measure Up To 20-Amps; This Troubleshooting Guide Assumes A Familiarity With The Use Of A Digital Multimeter; Make Sure That The Ac Electrical Socket The Charger Is Plugged Into Is In Good; Make Sure That The Ac Voltage At The Electrical Socket Is The Same As The Ac - Taylor-Dunn B0-248-48AC Operation, T Roubleshooting And Replacement Parts Manual

Equipped with ac motor peed control
Table of Contents

Advertisement

Electrical Troubleshooting
DEFINITIONS:
Volts Per Cell = Voltage for each cell in a battery pack. for example, one 6-volt battery has 3-cells.
Term
Value
V1:
See Chart
2.383 Volts Per Cell Gel Batteries
V2:
2.08 Volts Per Cell
A1:
2 to 4 Amps
All voltages are nominal.
This charger is rated for 115 VAC or 230
VAC operation (nominal). When switching
from one input voltage to the other, wait
until all LED's are off. Switching voltage
when any of the LED's are on will result in

damage to the charger.

TEST EQUIPMENT REQUIRED FOR TROUBLESHOOTING
Digital Multi Meter (DMM), calibrated and accurate down to 0.00001 volts.

Clamp on DC ammeter to measure up to 20-Amps.

Important Notes and Instructions
• This troubleshooting guide assumes a familiarity with the use of a digital multimeter including, voltage
tests, continuity tests and diode testing. If not familiar with any part of these tests, refer testing to a
qualified technician.
• Make sure that the AC electrical socket the charger is plugged into is in good working condition.
• Make sure that the AC voltage at the electrical socket is the same as the AC voltage on the charger
nameplate.

• Make sure the batteries are in good condition.

• If the charger exhibits intermittent problems, it must be in the failed mode for troubleshooting.

• There are no internally serviceable components in the charger. If the charger has failed then it must be

replaced.
Signet Charger Troubleshooting
Page 2
Condition
V1: Voltages are temperature compensated
Flooded batteries
relative to the temperature of the charger at the
time the charge cycle is started.
All batteries
Starting
All batteries
Temperature (C)
Less than -4
-4 to 2
2 to 8
8 to 14
14 to 21
GEL batteries must be charged with a
charger configured for GEL batteries. Use
of any other charger will result in damage
to the batteries and premature failure of
the batteries.
V1 Volts
Per Cell
2.64
2.61
2.59
2.56
2.54