Hardware Information
Allocation of the Display to Display Select Pins
The automatic configuration of one of 15 possible displays is effected via the
Display Select Inputs. The Display Select inputs are fitted with Pull-Up resistors,
i.e. if these inputs are not connected, they have a high level. In order to generate a
low level, the input must be connected to GND.
Nr.
LCD_SEL3
LCD_SEL2
0
low
1
low
2
low
3
low
4
low
5
low
6
low
7
low
8
high
9
high
10
high
11
high
12
high
13
high
14
high
15
high
8-28
LCD_SEL1
low
low
low
low
low
high
low
high
high
low
high
low
high
high
high
high
low
low
low
low
low
high
low
high
high
low
high
low
high
high
high
high
LCD_SEL0
Display Type
low
reserved
high
reserved
low
640 x 480 (VGA), D-STN, 16 bit
high
reserved
low
640 x 480 (VGA), TFT, 18 bit
high
reserved
low
1024 x 768 (XGA), TFT, 18 bit
high
800 x 600 (SVGA), TFT, 18 bit
low
reserved
high
reserved
low
reserved
high
reserved
low
reserved
high
reserved
low
reserved
high
No display / DDC selected
display