Installing A Remote Keypad Sounder (For Commercial Burglary Use Only); Figure 3-23: Remote Keyswitch Wiring; Figure 3-24: Remote Keypad Sounder Wiring - Honeywell VISTA-32FBPT Installation And Setup Manual

Commercial fire and burglary partitioned security system with scheduling
Hide thumbs Also See for VISTA-32FBPT:
Table of Contents

Advertisement

Wiring for the Remote Keyswitch
To install the ADEMCO 4146 keyswitch, perform the following steps:
Step
Action
1
Connect the ADEMCO 4146 to the panel as shown in Figure 3-23.
2
If you are using the tamper, make sure it is connected to a zone.

Installing a Remote Keypad Sounder (For Commercial Burglary use only)

An optional Amseco PAL 328N Piezo Sounder can be used to duplicate the sounds produced by the keypad's built-in
sounder. The remote sounder will duplicate all sounds (such as alarms, trouble beeps, etc.) except for the short beeps
associated with keypad key depression. One application of this feature would be to produce chime beeps at a distant
location from the keypads.
If used, program field 3∗20 must be set to "0" and field ∗15 must be set to the desired partition number.
The remote sounder must be connected to the Output 5 on the J2 connector as shown in Figure 3-24.
TO OUT 1 (J2 PIN 7)
TO GND (J2 PIN 8)
TO OUT 5 (J2 PIN 6)
TO ZONE 8 + (TERM 27)
TO ZONE 7/ZONE 8 - (TERM 26)
TO ZONE 7 + (TERM 25)

Figure 3-23: Remote Keyswitch Wiring

J2 CONNECTOR
1
2
3
4
5
6

Figure 3-24: Remote Keypad Sounder Wiring

(ARMED)
(READY)
RED
GREEN
820
820
OHMS
OHMS
2000
OHMS
TAMPER
SWITCH
(N.C.)
LOCK
SWITCH (N.O.)
2000
OHMS
EOLR
4146 KEYSWITCH
7
8
9
4142TR CABLE
BLACK
AMSECO PAL-328N
PIEZO SOUNDER
(10MA)
+
RED
45