The following is a typical display:
S Y S T E M 1 2
S T A T U S R N
Possible status indications include:
A = Armed Away
I = Armed Instant
B = Bypassed/Ready
F = Fire Alarm
To obtain more information regarding a particular partition, enter [∗] + Partition No. (e.g., [∗] + [2]). This allows viewing
only of that partition. In order to affect that partition, the user must use a code that has access to that partition. Also,
in order for a user of any partition to log on to Partition 3 to view the status of all partitions, that user must have access
to all partitions. Otherwise, access is denied.
The following is displayed for a fault condition on Zone 2 (Loading Dock Window) on Partition 1 (Warehouse) when a
user logs on from a keypad on Partition 2:
WHSE DISARMED
HIT ∗ FOR FAULTS
Pressing [∗] causes the following display to appear at Partition 1's keypad(s):
FAULT 02 LOADING
DOCK WINDOW
Additional zone faults are displayed one at a time. To display a new partition's status, press [∗] + Partition No.
The Armed LED on a Master keypad is lit only if all partitions have been armed successfully. The Ready LED is lit only
if all partitions are "ready to arm." Neither LED is lit if only some partitions are armed and/or only some partitions are
ready.
Press [∗] + [0] or [∗] + [3] to return to the master partition. Otherwise, if no keys are pressed for 2 minutes, the system
automatically returns to the master partition
The sounder on a Master keypad reflects the sound of the most critical condition on all of the partitions. The priority of
the sounds, from most to least critical, is as follows:
1.
Pulsing fire alarm sounds
2.
Steady burglar alarm sounds
3.
Trouble sounds (rapid beeping)
Silence the sounder by pressing any key on the Master keypad or a keypad on the partition where the condition exists.
A Master keypad uses the same panics as Partition 1. Master keypad panics are sent to Partition 1, and will activate
on Partition 1. Therefore, panics must be programmed for Partition 1.
Priority of Displays for Multi-Partition
This table shows the priority of displays if more than one of these conditions exists at the same time.
Priority
1
2
3
4
5
6
7
S = Armed Stay
R = Ready
∗ ∗ ∗ ∗ = Alarm
P = AC Power Failure
Description
Fire Alarm
All Other Alarms
AC Loss
Comm Fail
System Low Battery
Trouble
Bypass
M = Armed Maximum
N = Not Ready
T = Trouble
L = Low System Battery
Display
Priority
F
8
9
∗ ∗ ∗ ∗
P
10
C
11
L
12
T
13
B
20
C = Comm Fail
Description
Display
Not Ready
Ready
Armed STAY
Armed AWAY
Armed INSTANT
Armed MAXIMUM
N
R
S
A
I
M