Keyswitch Tamper Operation
The tamper switch need not be used for fire or UL
Household Burglary installations. For UL Commercial
Burglary installations, the tamper switch must be
wired to a zone (zone 6 in Figure 3-23).
Program that zone for Day Trouble/Night Alarm
(response type 5). When the keyswitch is removed from
the wall, the tamper switch opens, causing an alarm or
trouble on the zone. This also causes the control to
disable keyswitch operation until the tamper is restored
and the associated partition is disarmed.

Remote Keypad Sounder

An optional Amseco PAL 328N Piezo Sounder can be
used to duplicate the sounds produced by the keypad's
built-in sounder. The panel will remote all sounds (e.g.,
alarm, trouble, chime, entry/exit, etc.) produced by the
keypad's built-in sounder except for the short beeps
associated with keypad key depression. One application
of this feature might be to produce chime sounds at a
distant location from the panel's keypads.
Remote Keypad Sounder Setup
To setup for a remote keypad sounder, connect the piezo
sounder to the panel's positive auxiliary power output
and to Output 1 on the J7 connector as shown in Figure
3-24.
Program field 1✳46 Auxiliary Output Enable with a [2].
TO AUX POWER
(TERMINAL 6)
TO J7 / OUT 2
TO J7 / OUT 4
2K ELOR
+
ZONE
ZONE
TO ZONE 7 (+)
(TERMINAL 20)

Figure 3-23: Remote Keyswitch Wiring

WWW.DIYALARMFORUM.COM
Section 3 - Installing the Control
Wiring for the Remote Keyswitch
To install the 4146 keyswitch, perform the following
steps:
Step
Action
1
Connect the 4146 to the panel as shown in
Figure 3-23.
2
If you are using the tamper, make sure it is
connected to a zone.
YELLOW
WHITE
RED
GREEN
(ARMED)
(READY)
820
820
ohms
ohms
RED
BLACK
TAMPER SWITCH
(CONTACTS CLOSE WHEN
SWITCH DEPRESSED).
LOCK SWITCH
(NORMALLY OPEN)
2K ELOR
IF USED.
1. OUT 1 IS NO LONGER
USABLE FOR SMOKE
DETECTOR RESET
OR GROUND START
(SEE FIELD 1*46).
2. OUT 2, 3, 4 CAN STILL BE
BLACK
USED TO PROVIDE ALARM
STATUS INDICATIONS OR
TO OPERATE A KEYSWITCH
(SEE FIELD *15).
+
TO AUX POWER +
RED
TERMINAL 6
10mA CURRENT DRAIN)

Figure 3-24: Remote Keypad Sounder Wiring

J7_keyswitch
4142TR CABLE
GRAY (GROUND)
YELLOW (OUT 1)
WHITE (GROUND)
RED (OUT 2)
AMSECO PAL-328N
PIEZO SOUNDER
GREEN (GROUND)
BROWN (OUT 3)
BLUE (GROUND)
BLACK (OUT 4)
J7 CONNECTOR
J7_trigcon-001-V0
3-19