Dr 34 Ascii Main Display Value; Table 8- 14 Assignment Of Data Record 34 - Siemens SIWAREX WP321 Manual

Electronic weighing system
Hide thumbs Also See for SIWAREX WP321:
Table of Contents

Advertisement

Scale parameters and functions

8.16 DR 34 ASCII main display value

8.16
DR 34 ASCII main display value
The ASCII weight corresponds to the value on the main display of the scales and can be
used for a supplementary display as well as the legal trade main display.
Table 8- 14
Assignment of data record 34
Variable
Note
Data record
Contains no. of data record
number
Length
Data record length information
Application
Information about which application
the DR belongs to
Version identi-
Information on the current data
fier
record version
ASCII display
Maximum length and actual length
string header
of string
Content of
For display of the weight value and
main display
other current values (see below)
as ACII string
(Page 83)
82
Type
L
USHORT
2
USHORT
2
USHORT
2
USHORT
2
UBYTE[2]
2
CHAR[16]
16
Rw
Default
Min.
r
34
-
r
26
-
r
201
-
r
1
1
r
16,2
-
r
" "
-
Manual, 07/2014, A5E33715669A-02
Max.
-
-
-
65 635
-
-
SIWAREX WP321

Advertisement

Table of Contents
loading

Table of Contents