DR 6 limit value settings

The switch-on and switch-off values for the limits are configured in data record DR 6.
Procedure
● Check all parameters and modify them as required
● Transfer the data record to the scale
Table 8- 4
Assignment of data record 6
Variable
Note
Data record
Contains no. of data rec-
number
ord
Length
Data record length infor-
mation
Application
Information about which
application the DR be-
longs to
Version identi-
Information on the current
fier
data record version
DR 6 limit
Gross / net basis of limit
value settings
values 1 and 2
(Page 61)
0: Limit value 1 and limit
value 2 are based on the
gross value
1: Limit value 1 and limit
value 2 are based on the
net value
Reserve
Reserve
Limit value 1
Switch-on point for limit
ON (Page 63)
value 1 (% of measuring
range)
Reserve
Reserve
Limit value 1
Switch-off point for limit
OFF
value 1 (% of measuring
(Page 63)
range)
Reserve
Reserve
Limit value 2
Switch-on point for limit
ON (Page 63)
value 2 (% of measuring
range)
SIWAREX WP321
Manual, 07/2014, A5E33715669A-02
Type
L
USHORT
2
USHORT
2
USHORT
2
USHORT
2
USHORT
2
USHORT
2
FLOAT
4
TIME
4
FLOAT
4
TIME
4
FLOAT
4
Scale parameters and functions
8.7 DR 6 limit value settings
Rw
Default
r
6
r
60
r
201
r
1
rw
0
rw
0
rw
0
rw
0
rw
0
rw
0
rw
0
Min.
Max.
-
-
-
-
-
-
1
65 635
0
1
0
-
maxi-
maxi-
mum
mum
number
number
range
range
0
maxi-
mum
number
range+
maxi-
maxi-
mum
mum
number
number
range
range
0
maxi-
mum
number
range+
maxi-
maxi-
mum
mum
number
number
range
range
61

Advertisement

Table of Contents
loading

Table of Contents