Dr 32 Message Display; Table 8- 13 Assignment Of Data Record 32 - Siemens SIWAREX WP321 Manual

Electronic weighing system
Hide thumbs Also See for SIWAREX WP321:
Table of Contents

Advertisement

8.15

DR 32 Message display

Data record 32 indicates all pending message bits. The bit "Error status changed" is present
in the status bits of the DR30. If this bit is set, the message area of the DR32 has been
changed.
The DR32 indicates which message has been newly added or deleted. The data record is
automatically read by the SIMATIC FB in the event of an error. Following successful reading,
the status bit is reset in DR30.
Table 8- 13
Assignment of data record 32
Variable
Note
Data record
Contains no. of data record
number
Length
Data record length information
Application
Information about which application the
data record belongs to
Version identi-
Information on the current data record
fier
version
1000
Operator error
Reserve
-
1104
Undervoltage
Reserve
-
1105
Overload
1106
Underload
1002
RAM error
1102
ADC error
1005
Hardware interrupt lost
1003
Checksum error data
Reserve
-
1004
Checksum error program
Reserve
-
1001
RESET / restart following error
Reserve
-
Reserve
-
2000
Technology error
2001
Taring or zeroing timeout
Reserve (14
-
bits)
5000
Data or operating error exists
5001
Command code or data record unknown BIT
Reserve
-
5003
Leaving calibration mode not possible
5004
Command or data transmission only
available in service mode
SIWAREX WP321
Manual, 07/2014, A5E33715669A-02
Type
L
USHORT
2
USHORT
2
USHORT
2
USHORT
2
BIT
2
BIT
BIT
BIT
BIT
BIT
BIT
BIT
BIT
BIT
BIT
BIT
BIT
BIT
BIT
BIT
BIT
2
BIT
BIT
BIT
2
BIT
BIT
BIT
Scale parameters and functions
8.15 DR 32 Message display
Rw
Default Min.
r
32
-
r
26
-
r
101
-
r
1
1
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
Max.
-
-
-
65 635
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
79