Dr 5 Zeroing Memory; Table 8- 3 Assignment Of Data Record 5 - Siemens SIWAREX WP321 Manual

Electronic weighing system
Hide thumbs Also See for SIWAREX WP321:
Table of Contents

Advertisement

8.6

DR 5 zeroing memory

Data record DR 5 displays the current values in the tare memory and the zeroing memory.
Procedure
● Check all parameters
● Transfer the data record to the scale
Table 8- 3
Assignment of data record 5
Variable
Note
Data record
Contains no. of data
number
record
Length
Data record length infor-
mation
Application
Information about which
application the DR be-
longs to
Version identifi-
Information on the cur-
er
rent data record version
Effective tare
Current tare weight from
weight - from
specification as process
specification
value
(Page 60)
Effective tare
Current tare weight from
weight (semi-
semi-automatic mode as
automatic)
process value
(Page 60)
Reserve
Reserve
Zero weight
Current zeroing weight
(semi-
(affected by zeroing)
automatic)
(Page 60)
Current zero
Zero point correction
tracking weight
weight affected by auto-
(Page 60)
matic zeroing
Dead load
Dead load determined
(Page 60)
during calibration
Reserve 1
Reserve
Reserve 2
Reserve
Reserve 3
Reserve
SIWAREX WP321
Manual, 07/2014, A5E33715669A-02
Type
L
USHORT
2
USHORT
2
USHORT
2
USHORT
2
FLOAT
4
FLOAT
4
FLOAT
4
FLOAT
4
FLOAT
4
FLOAT
4
SHORT
2
USHORT
2
FLOAT
4
Scale parameters and functions
8.6 DR 5 zeroing memory
Rw
Default
Min.
r
5
-
r
40
-
r
201
-
r
1
1
rw
0
0
rw
0
0
rw
0
-
rw
0
Depends
on specifi-
cation in
DR 3
rw
0
Depends
on specifi-
cation in
DR 3
r
0
Depends
on specifi-
cation in
DR 3
rw
0
-
rw
0
-
rw
0
-
Max.
-
-
-
65 635
Depends
on specifi-
cation in
DR 3
Depends
on specifi-
cation in
DR 3
-
Depends
on specifi-
cation in
DR 3
Depends
on specifi-
cation in
DR 3
Depends
on specifi-
cation in
DR 3
-
-
-
59