Dr 14 Simatic Interface Parameters; Table 8- 8 Assignment Of Data Record 14 - Siemens SIWAREX WP321 Manual

Electronic weighing system
Hide thumbs Also See for SIWAREX WP321:
Table of Contents

Advertisement

8.11

DR 14 SIMATIC interface parameters

The parameters which define the response of the SIMATIC interface are specified in data
record DR 14. It is possible to define the process values to be output on the basis of the I/O
area.
Procedure
● Check the parameters and modify them as required
● Transfer the data record to the scale
Table 8- 8
Assignment of data record 14
Variable
Note
Data record
Contains no.
number
of data rec-
ord
Length
Data record
length infor-
mation
Application
Information
about which
application
the DR be-
longs to
Version iden-
Information
tifier
on the cur-
rent data
record ver-
sion
Selection of
Code for the
process val-
selection of
ue 1, 2
the process
(Page 72)
variable to be
updated
Selection of
Code for the
process val-
selection of
ue 1, 2
the process
(Page 72)
variable to be
updated
Reserve 1
Reserve
Reserve 2
Reserve
SIWAREX WP321
Manual, 07/2014, A5E33715669A-02
Type
L
USHORT
2
USHORT
2
USHORT
2
USHORT
2
USHORT
2
USHORT
2
SHORT
2
USHORT
2
8.11 DR 14 SIMATIC interface parameters
Rw
Default
r
14
r
16
r
201
r
1
rw
4
rw
6
rw
0
rw
0
Scale parameters and functions
Min.
Max.
-
-
-
-
-
-
1
65 635
0
10
0
10
0
-
0
-
71

Advertisement

Table of Contents
loading

Table of Contents