RS485 interface
Standard
Baud rate
Data bits
Parity
Stop bits
Terminating resistors (can be activated)
Electrical isolation
Transfer protocol
Cable length
Dimensions and weights
Dimensions
Mechanical requirements and data
Testing
Vibrational load during
operation
Shock load during opera-
tion
Vibration load during
transport
Shock load during
transport
Free fall
SIWAREX WP321
Manual, 07/2014, A5E33715669A-02
Width
Weight, approx.
Standards
IEC 61131-2
IEC 60068-2-6
Test Fc
IEC 61131-2
IEC 60068-2-27
Test Ea
IEC 60068-2-6
Test Fc
IEC 60068-2-27:
Test Ea
IEC 61131-2
IEC 60068-2-31:
Test Ec, procedure 1
12.1 Technical specifications
EIA-485
up to 115 kbps*
7 or 8
even | odd | none
1 or 2
390 Ω / 220 Ω / 390 Ω
500 V AC
ASCII for remote display from Siebert and Mod-
bus RTU for HMI or third-party systems.
≤ 115 kbps max. 1 000 m
(fieldbus cable 2-wire, shielded, e.g. 6XV1830-
0EH10)
15 mm
31 g
Test values
5 to 8.4 Hz: 3.5 mm out.
8.4 to 150 Hz: 9.8 m/s
150 m/s
(approx. 15 g), half sine
2
5 to 8.4 Hz: 3.5 mm out.
8.4 Hz to 500 Hz: 9.8 m/s
250 m/s
(25G), half sine
2
In product packaging:
300 mm drop height
In shipping package:
1.0 m drop height
Technical data
(=1G)
2
2