Dr 31 Advanced Current Process Values; Unfiltered Digit Value; Filtered Digit Value; Table 8- 12 Assignment Of Data Record 31 - Siemens SIWAREX WP321 Manual

Electronic weighing system
Hide thumbs Also See for SIWAREX WP321:
Table of Contents

Advertisement

8.14

DR 31 advanced current process values

Current states and process values in the scales can be monitored using advanced process
values and process values (DR 30). This data is not required for standard operation of the
scales.
Monitoring selected data during trial operation is extremely useful as it helps you to optimize
parameters.
Procedure
● Read data record DR 31
● Display/analyze the required tags
Table 8- 12
Assignment of data record 31
Variable
Note
Data record
Contains no. of data record
number
Length
Data record length information
Application
Information about which applica-
tion the data record belongs to
Version iden-
Information on the current data
tifier
record version
Unfiltered
Unfiltered digit value of AD con-
digit value
verters / digital load cells
(Page 77)
Filtered digit
Filtered digit value of AD convert-
value
ers / digital load cells after dig.
(Page 77)
filter 1
Reserve 1
Refresh
Refresh counter incremented by 1
counter for
if weight values have been
process val-
changed
ues
(Page 78)
Reserve 2
8.14.1

Unfiltered digit value

The unfiltered digit value is the internal measured value immediately before filtering.
8.14.2

Filtered digit value

The filtered digit value is the internal measured value immediately after filtering.
SIWAREX WP321
Manual, 07/2014, A5E33715669A-02
8.14 DR 31 advanced current process values
Type
L
USHORT
2
USHORT
2
USHORT
2
USHORT
2
LONG
4
LONG
4
SHORT
2
USHORT
2
FLOAT
4
Scale parameters and functions
Rw
Default
Min.
r
31
-
r
24
-
r
201
-
r
1
1
r
0
-
r
0
-
r
0
-100
r
0
-
r
0
-
Max.
-
-
-
65 635
-
-
100
-
-
77

Advertisement

Table of Contents
loading

Table of Contents