Scale parameters and functions
8.3 DR 3 calibration parameters
Variable
Note
Standstill
Waiting time until standstill.
waiting time
0: Any scale commands dependent
(Page 52)
on standstill are rejected immediately
in the absence of standstill.
>0: Maximum waiting time until
command is executed
Low-pass
Low-pass filter limit frequency:
filter limit
0: Filter disabled
frequency
(Page 52)
Low-pass
Filter number 2*(1...5)
filter number
(Page 52)
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Mean value
Filter for digit values,
filter depth
permitted filter depth: 0 ... 250
(Page 53)
Parameter for calculation of calibration points
1)
8.3.1

Scale name

You can select any name, but it may not exceed 12 characters. You can enter any
designation.
8.3.2

Unit of weight

A string with up to four digits can be specified as the unit of weight, e.g.: t, kg, lbs. The
defined unit of weight applies to all weight specifications. Entries are not be converted if the
unit of weight has changed. Entries must be left-aligned.
8.3.3

Gross identifier

The gross identifier specifies the letter, B (for brutto) or G (for gross), to be used in the
display for gross weights.
48
Type
Length
Rw
(bytes)
TIME
4
rw
FLOAT
4
rw
USHORT
2
rw
USHORT
2
rw
FLOAT
4
rw
USHORT
2
rw
USHORT
2
rw
Default
Min.
2 000
0
0,5
tbd
4
2
0
-
0
tbd
4
2
10
0
SIWAREX WP321
Manual, 07/2014, A5E33715669A-02
Max.
10 000
tbd
10
-
tbd
10
250