Siemens SENTRON PAC4200 Manual page 177

Power monitoring device
Hide thumbs Also See for SENTRON PAC4200:
Table of Contents

Advertisement

Name
Maximum THD voltage b
Maximum total harmonic distortion of the voltage between phase conductor b and the neutral
conductor referred to the fundamental
THD voltage c
Total harmonic distortion of the voltage between phase conductor c and the neutral conductor referred
to the fundamental
Maximum THD voltage c
Maximum total harmonic distortion of the voltage between phase conductor c and the neutral
conductor referred to the fundamental
THD Voltage a-b
Total harmonic distortion of the voltage between phase conductors a and b referred to the
fundamental
Maximum THD voltage a-b
Maximum THD voltage for a-b referred to the fundamental
THD voltage b-c
Total harmonic distortion of the voltage between phase conductors b and c referred to the
fundamental
Maximum THD voltage b-c
Maximum THD voltage for b-c referred to the fundamental
THD voltage c-a
Total harmonic distortion of the voltage between phase conductors c and a referred to the
fundamental
Maximum THD voltage c-a
Maximum THD voltage for c-a referred to the fundamental
THD Current a
Total harmonic distortion of the current in phase conductor a referred to the fundamental
Maximum THD current a
Maximum total harmonic distortion of the current in phase conductor a referred to the fundamental
THD current b
Total harmonic distortion of the current in phase conductor b referred to the fundamental
Maximum THD current b
Maximum total harmonic distortion of the current in phase conductor b referred to the fundamental
THD current c
Total harmonic distortion of the current in phase conductor c referred to the fundamental
Maximum THD current c
Maximum total harmonic distortion of the current in phase conductor c referred to the fundamental
Apparent Energy Tariff 1
Apparent energy at tariff 1
Apparent energy tariff 2
Apparent energy at tariff 2
SENTRON PAC4200
Manual, 09/2008, A5E02316180B-01
Abbrev.
Abbrev.
DE + IEC
EN + NAFTA
THD
THD
U L2 max
V b max
THD
THD
U L3
V c
THD
THD
U L3 max
V c max
THD
THD
U L1-L2
V a-b
THD
THD
U L1-L2 max
V a-b max
THD
THD
U L2-L3
V b-c
THD
THD
U L2-L3 max
V b-c max
THD
THD
U L3-L1
V c-a
THD
THD
U L3-L1 max
V c-a max
THD
THD
I L1
I a
THD
THD
I L1
I a
THD
THD
I L2
I b
THD
THD
I L2
I b
THD
THD
I L3
I c
THD
THD
I L3
I c
E
VAh
ap T1
E
VAh
ap T2
Appendix
A.1 Measured variables
Unit
Dis-
LIM
play
SOURCE
%
12.1
%
12.0
THD-V c
%
12.1
%
12.2
THD-V ab
%
12.3
%
12.2
THD-V bc
%
12.3
%
12.2
THD-V ca
%
12.3
%
13.0
THD-I a
%
13.1
%
13.0
THD-I b
%
13.1
%
13.0
THD-I c
%
13.1
VAh
18.0
VAh
18.0
177

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents