Name
Minimum reactive power b (VARn)
Minimum value of the reactive power of the harmonics in phase conductor b referred to the load
counting system, measured according to VARn
Reactive power c (VARn)
Reactive power of the harmonics in phase conductor c referred to the load counting system,
measured according to VARn
Maximum reactive power c (VARn)
Maximum value of the reactive power of the harmonics in phase conductor c, measured according to
VARn
Minimum reactive power c (VARn)
Minimum value of the reactive power of the harmonics in phase conductor c referred to the load
counting system, measured according to VARn
Reactive Power a (VAR1)
Reactive power of the fundamental in phase conductor a referred to the load counting system,
measured according to VAR1
Maximum reactive power a (VAR1)
Maximum reactive power of the fundamental in phase conductor a referred to the load counting
system, measured according to VAR1
Minimum reactive power a (VAR1)
Minimum reactive power of the fundamental in phase conductor a referred to the load counting
system, measured according to VAR1
Reactive power b (VAR1)
Reactive power of the fundamental in phase conductor b referred to the load counting system,
measured according to VAR1
Maximum reactive power b (VAR1)
Maximum reactive power of the fundamental in phase conductor b referred to the load counting
system, measured according to VAR1
Minimum reactive power b (VAR1)
Minimum reactive power of the fundamental in phase conductor b referred to the load counting
system, measured according to VAR1
Reactive power c (VAR1)
Reactive power of the fundamental in phase conductor c referred to the load counting system,
measured according to VAR1
Maximum reactive power c (VAR1)
Maximum reactive power of the fundamental in phase conductor c referred to the load counting
system, measured according to VAR1
Minimum reactive power c (VAR1)
Minimum reactive power of the fundamental in phase conductor c referred to the load counting
system, measured according to VAR1
Total Apparent Power
Total apparent power in the phase conductors
Maximum total apparent power
Maximum value of the total apparent power in the three-phase system
Minimum total apparent power
Minimum value of the total apparent power in the three-phase system
SENTRON PAC4200
Manual, 09/2008, A5E02316180B-01
Abbrev.
Abbrev.
DE + IEC
EN + NAFTA
Q
VAR
n L2 min
n b min
Q
VAR
n L3
n c
Q
VAR
n L3 max
n c max
Q
VAR
n L3 min
n c min
Q
VAR
1 L1
1 a
Q
VAR
1 L1 max
1 a max
Q
VAR
1 L1 min
1 a min
Q
VAR
1 L2
1 b
Q
VAR
1 L2 max
1 b max
Q
VAR
1 L2 min
1 b min
Q
VAR
1 L3
1 c
Q
VAR
1 L3 max
1 c max
Q
VAR
1 L3 min
1 c min
S
VA
S
VA
max
max
S
VA
min
min
Appendix
A.1 Measured variables
Unit
Dis-
LIM
play
SOURCE
VAR
6.2
VAR
6.0
VARn c
VAR
6.1
VAR
6.2
VAR
6.0
VAR1 a
VAR
6.1
VAR
6.2
VAR
6.0
VAR1 b
VAR
6.1
VAR
6.2
VAR
6.0
VAR1 c
VAR
6.1
VAR
6.2
VA
7.0
ΣVA
VA
7.1
VA
7.2