B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 22 of 55)
ADDR
REGISTER NAME
60E3
Breaker 2 Auxiliary Contact
60E4
Breaker 2 Supervision Element
60E5
Weak-Infeed Keying
60E6
Supervision Element
60E7
Infeed Pickup Delay
B
60E8
Infeed Reset Delay
60E9
Open Breaker Keying Pickup Delay
60EA
Open Breaker Keying Reset Delay
Phase Comparison Trip Scheme (Read/Write Grouped Setting)
60F0
87PC Function
60F1
87PC Channel Loss
60F2
87PC Block
60F3
87PC Target
60F4
87PC Events
60F5
87PC Scheme Select
60F6
87PC Scheme Signal
60F7
87PC Signal Source
60F8
87PC FDL Pickup
60FA
87PC FDH Pickup
60FB
87PC Mixed Signal K
60FE
87PC Phase Delay Ch1
6100
87PC Phase Delay Ch2
6106
87PC Transient Pickup
610A
87PC Asymmetry Channel 1
610E
87PC Asymmetry Channel 2
6110
87PC Stability Angle
6112
87PC Transient Reset
6113
87PC Received Volts Channel 1
6114
87PC Received Volts Channel 2
6115
87PC High-Speed Contact 1
6116
87PC High-Speed Contact 2
6117
87PC FDL AUX
6118
87PC FDH AUX
6119
87PC Reset Delay
611A
87PC Mixed Signal Reference Angle
611B
87PC Trip Security
611C
87PC Second Coincidence Timer
611D
87PC Enhanced Stability Angle
611E
87PC FDH Supervision
611F
87PC Pickup Delay
6120
87PC Stop Tx
6121
87PC Tx Reset Delay
CT Failure Detector (Read/Write Setting)
6124
CT Fail Function
6125
CT Fail Block
6126
CT Fail Current Source 1
6127
CT Fail Current Pickup 1
6128
CT Fail Current Source 2
6129
CT Fail Current Pickup 2
612A
CT Fail Voltage Source
612B
CT Fail Voltage Pickup
612C
CT Fail Pickup Delay
612D
CT Fail Target
612E
CT Fail Events
B-30
RANGE
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 50
0 to 50
0 to 50
0 to 50
0 to 1
0 to 500
0 to 65535
0 to 2
0 to 1
0 to 8
0 to 1
0 to 5
0.01 to 15
0.01 to 15
0 to 0.25
0 to 65.535
0 to 65.535
0 to 65.535
–20 to 20
–20 to 20
40 to 140
0 to 65.535
0 to 125
0 to 125
0 to 64
0 to 64
0 to 65535
0 to 65535
0 to 200
0 to 359
0 to 1
10 to 200
40 to 180
0 to 65535
0 to 50
0 to 65535
0 to 1000
0 to 1
0 to 65535
0 to 5
0 to 2
0 to 5
0 to 2
0 to 5
0 to 2
0 to 65.535
0 to 2
0 to 1
L60 Line Phase Comparison System
UNITS
STEP
FORMAT
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
---
1
F102
ms
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F149
1 (2TL-BL-DPC-3FC)
---
1
F150
0 (MIXED I_2 - K*I_1)
---
1
F167
pu
0.01
F001
pu
0.01
F001
---
0.01
F001
ms
0.001
F003
ms
0.001
F003
s
0.001
F003
ms
0.1
F004
ms
0.1
F004
degrees
10
F003
s
0.001
F003
V
0.1
F001
V
0.1
F001
---
1
F490
---
1
F490
---
1
F300
---
1
F300
ms
1
F001
°
1
F001
---
1
F534
0 (First Coincidence)
ms
1
F001
°
5
F001
---
1
F300
ms
1
F001
---
1
F300
ms
1
F001
---
1
F102
---
1
F300
---
1
F167
pu
0.1
F001
---
1
F167
pu
0.1
F001
---
1
F167
pu
0.01
F001
s
0.001
F001
---
1
F109
---
1
F102
APPENDIX B
DEFAULT
0
0
0
0
0
35
0
0
0 (Disabled)
0
0
0 (Self-reset)
0 (Disabled)
0 (SRC 1)
50
75
20
0
0
30
0
0
75
30
120
120
0
0
0
0
30
0
40
110
0
0
0
0
0 (Disabled)
0
0 (SRC 1)
2
1 (SRC 2)
2
0 (SRC 1)
20
1000
0 (Self-reset)
0 (Disabled)