Natural Gas - 600RC
Has a maximum (both burners HIGH) NG input of 6.0kw (Gross)
Has a medium (both burners LOW/front burner only HIGH) NG input of 3.2kw (Gross)
Has a minimum (front burner only LOW) NG input of 2.4kw (Gross)
Natural Gas - 600FS
Has a maximum (both burners HIGH) NG input of 6.0kw (Gross)
Has a medium (front burner only HIGH) NG input of 3.2kw (Gross)
Has a minimum/Ignition (front burner only LOW) NG input of 2.4kw (Gross)
Natural Gas - 800RC
Has a maximum (both burners HIGH) NG input of 6.4kw (Gross)
Has a medium (both burners LOW/front burner only HIGH) NG input of 3.3kw (Gross)
Has a minimum (front burner only LOW) NG input of 2.4kw (Gross)
Natural Gas - 800FS
Has a maximum (both burners HIGH) NG input of 6.4kw (Gross)
Has a medium (front burner only HIGH) NG input of 3.3kw (Gross)
Has a minimum/Ignition (front burner only) NG input of 2.4kw (Gross)
When operating your fire for the first time, some vapours may be given off which may
cause a slight odour and could possibly set off any smoke alarms in the immediate
vicinity. These vapours are quite normal with new appliances. They are totally harmless
and will disappear after a few hours use.

The Oxysafe flame sensing and flue blockage safety system.

For your safety, this appliance is fitted with a flue blockage safety device which will
shut down the appliance in the event of abnormal flue conditions. This device is
NOT a substitute for an independently mounted Carbon Monoxide detector.
The device will also automatically shut off the gas supply to the fire if the pilot flame
goes out due to lack of oxygen or for any other reason.
If this device starts to repeatedly shut off the gas, get expert advice.
This device incorporates a probe which senses that the heat from the pilot flame is
correct. If this probe is cool, the device will prevent any gas flow unless the control
knob is held in at the ignition position.
If, for any reason, the flames go out when the fire is hot or if the fire is turned off
when hot, always wait at least three minutes before attempting to relight.
©
GDC Group Ltd. AUG 2016

GAS CONSUMPTION

OPERATING YOUR FIRE

PLEASE NOTE
Page 50