8. Fasten the coaxial connector to the waveguide flange with three sets of M620
hex bolts, M6 spring washers and M6 nuts.
9. Tape the cable with two or more turns of
self-bonding tape then wrap with PVC
tape.
10. Secure the cable with fixing bands (sup-
plied) or the optional clamping metal (Type: 03-011-3228,
Code no.: 100-049-620) to the mast and to the wheel-
house structure. For the optional through-deck cable
gland, see the outline drawing at the back of this manual.
11. DE-ICER INSTALLATION. Follow all steps if the de-icer is not already installed.
(See also "X-band De-icer Kit Installation Instructions", issued separately.) If the
de-icer is already installed, do only steps 1) through 7). If the de-icer is not provid-
ed, go to step 12.
1) Unfasten the clamping gland for the de-icer's power cable, then remove the
gasket, flat washers and cover.
2) Slide the clamping gland, flat washer, gasket and flat washers in that order
onto the cable as shown in step 4 on page 2-13.
Nut
Hex bolt
Spring
washer
DE-ICER Board (03P9573)
5 cm
ø7
[TEST] button
[TEST] button
Voltage Selection switch
TB901
TB901
2. WIRING
Coaxial
connector
Fixing band
2-15