ALLIANCE CDS9GC Installation & Operation Manual page 15

Stacked clothes dryers nonmetered and metered electric and gas models
Table of Contents

Advertisement

5
B
A
30°
1
NOTE: Where the exhaust duct pierces a
combustible wall or ceiling, the opening
must be sized per local codes.
2
Wall
2
1
CONNECT TO DRYER
4
VERTICAL EXHAUST INSTALLATION
1
Roof
2
Wall
3
5 cm (2 in.) Minimum
4
NOTE: Where the exhaust duct pierces a
combustible wall or ceiling, an opening
must be sized as shown or per local
codes.
Figure 7
512691R4
C
D
E
F
G
H
HORIZONTAL EXHAUST INSTALLATION
3
H319I
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
K
1
I
J
AIR
FLOW
EXHAUST AIR FLOW
MAXIMUM LENGTH OF
DUCT 9.1 m (30 feet)
3
Clearance per Local Codes
4
No Screen or Cap
5
Clean Out Cover – Inspect Monthly
Figure 6
To reduce the risk of fire and the
accumulation of combustion gases, DO NOT
exhaust dryer air into a window well, gas
vent, chimney or enclosed, unventilated
area, such as an attic, wall, ceiling, crawl
space under a building or concealed space
of a building.
Duct Station
A
B
C
D
E
F
G
H
I
J
K
A Backdraft Damper, Part No. 58786 (obtain locally),
should be installed in a 10.2 cm (4 inch) diameter
VERTICAL duct system. This will prevent a backdraft
when dryer is not in use, and will keep the exhaust air
in balance within the central exhaust system.
Installation
2
3
4
EXHAUST
OUTLET
WARNING
Minimum Diameter of
Collector Duct
10.2 cm (4 inches)
20.3 cm (8 inches)
22.9 cm (9 inches)
25.4 cm (10 inches)
27.9 cm (11 inches)
30.5 cm (12 inches)
32.6 cm (13 inches)
35.6 cm (14 inches)
38.1 cm (15 inches)
38.1 cm (15 inches)
40.6 cm (16 inches)