Step 7: Recheck Steps 1-6; Step 8: Check Heat Source - ALLIANCE CDS9GC Installation & Operation Manual

Stacked clothes dryers nonmetered and metered electric and gas models
Table of Contents

Advertisement

Installation
Earthing Instructions
Each dryer must be earthed. In the event of
malfunction or breakdown, earthing will reduce the
risk of electric shock by providing a path of least
resistance for electric current. Each dryer is equipped
with a cord having an equipment-earthing conductor
and a 3-prong earthing plug. The plug must be plugged
into an appropriate outlet that is properly installed and
earthed in accordance with local codes and ordinances.
WARNING
Improper connection of the equipment-
earthing conductor can result in a risk of
electric shock. Check with a qualified
electrician or serviceman if you are in
doubt as to whether the dryer is properly
earthed.
20
W159
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Do not modify the plug provided with the dryer – if it
will not fit the outlet, have a proper outlet installed by
a qualified electrician.
If the electrical supply does not meet the above
specifications and/or you are not sure your building
has an effective earth, have a qualified electrician or
your local electrical utility company check it and
correct any problems.

Step 7: Recheck Steps 1-6

Refer to Installer Checklist on the back cover of this
manual and make sure that dryer is installed correctly.

Step 8: Check Heat Source

Electric Dryers
Close the loading door and start the dryer in a heat
setting (refer to the Operation section). After the dryer
has operated for three minutes, the exhaust air or
exhaust pipe should be warm.
Gas Dryers
IMPORTANT: This operation is to be conducted
by qualified personnel only.
To view the burner flame, remove the lower front
panel of the dryer.
Close the loading door, start the dryer in a heat setting
(refer to the Operation section). The dryer will start,
the igniter will glow red and the main burner will
ignite.
IMPORTANT: If all air is not purged out of gas
line, gas igniter may go off before gas is ignited. If
this happens, after approximately two minutes
igniter will again attempt gas ignition.
IMPORTANT: If igniter does not light, make sure
gas is turned on.
512691R4