Connect Dryer Exhaust System - ALLIANCE Dryers Installation Instructions Manual

Table of Contents

Advertisement

Area
A*
B
C
D
E
F
G
H
*
NOTE: For new installations, locate top of wall vent 42
inches (106.7 cm) above floor to make venting easier to
connect.
IMPORTANT: In mobile home installations, gas dryers
MUST be permanently attached to the floor at the time
of installation. Order No. 526P3 Dryer Installation Kit
(available at extra cost) for a manufactured (mobile)
home installation. Follow the instructions supplied with
the kit.

Connect Dryer Exhaust System

To reduce the risk of fire and the accumulation of
combustion gases, DO NOT exhaust dryer air into a
window well, gas vent, chimney or enclosed, unven-
tilated area, such as an attic, wall, ceiling, crawl
space under a building or concealed space of a
building.
Part No. 510963R7
Description
Dryer sides and rear clearance
Dryer top clearance
Dryer front clearance
Exhaust duct clearance to com-
bustible material
Weather hood to ground clear-
ance
Distance from floor or ceiling
to air opening edge
Area of centered air openings
in closet door. Louvered door
with equivalent air openings is
acceptable. (Minimum clearan-
ces are shown.)
For new installations, locate
top of wall vent 42 inches
[1067 mm] above floor to make
venting easier to connect.
Rear clearance is minimum. 2 inches [51 mm] is recommended for utility connection. 6 inches
[152 mm] is recommended when venting through rear of unit.
WARNING
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
Free Standing/Alcove In-
stallation
0 in. [0 mm]
12 in. [305 mm]
Not Applicable
2 in. [51 mm]
12 in. [305 mm]
Not Applicable
Not Applicable
42 in. [1067 mm]
Table 1
A clothes dryer produces combustible lint. To re-
duce the risk of fire and combustion gas accumula-
tion the dryer MUST be exahusted to the outdoors.
This gas appliance contains or produces a chemical
or chemicals which can cause death or serious ill-
ness and which are known to the State of California
to cause cancer, birth defects, or other reproductive
harm. To reduce the risk from substances in the fuel
or from fuel combustion, make sure this appliance is
installed, operated, and maintained according to the
instructions in this manual.
W045
Closet Installation
0 in. [0 mm]
12 in. [305 mm]
2 in. [51 mm]
2 in. [51 mm]
12 in. [305 mm]
3 in. [76 mm]
40 sq. in./open [260 sq. cm/
open]
42 in. [1067 mm]
WARNING
WARNING
Installation
W116
W115
9