Six-Conductor Connection To The Line Supply - Siemens Simodrive 611 Configuration Manual

Drive converters
Hide thumbs Also See for Simodrive 611:
Table of Contents

Advertisement

8 Important Circuit Information
8.15 Examples of correctly and incorrectly connecting NE
8.15.2
Six–conductor connection to the line supply
Schematic diagram
Filter (5 kW)
F
(T10 A)
N
2L1
2L2
2L3
Filter (X kW)
F
(X A)
L
N
1L1
1L2
1L3
PE
Note:
1) L
for 5 kW and 10 kW integrated, therefore not necessary here!
k
2) DC link connection not permissible for six–conductor connection to the line supply!
Fig. 8-33
Examples for correct six–conductor connection to the line supply with a maximum of four monitoring modules
connected to a line infeed module (NE module)
8-316
Note
S
All X181 connections of a drive group must be electrically switched in
parallel!
S
All of the jumpers at X181 must be removed!
S
A maximum of four monitoring modules may be connected at X181 of an
NE module.
S
If a DC link is buffered (DC link connection), the voltage must always be
taken from between the reactor (L
S
Different line supplies may be used, e.g. using UPS.
S
For all of the following examples, cables must be routed so that they are
short–circuit and ground–fault proof (or fuse)!
NE
e.g. NCU PMxx
X181
M500
P500
2U1
1U1
2V1
1V1
2W1
2)
1W1
Twisted
cable
P600
M600
1)
U1
V1 W1
PE
K
) and the line supply infeed (NE).
K
Correct!
PMxx
Six–conductor connection
to the line supply
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
05.08
05.01
v4 MM
MM
PMxx
X181
M500
P500
2U1
1U1
2V1
1V1
2W1
1W1