8 Important Circuit Information
8.15 Examples of correctly and incorrectly connecting NE
Schematic diagram
Filter (5 kW)
F
(X A)
N
L1
L2
L3
1)
Filter (X kW)
F
(X A)
L
N
L1
L2
L3
PE
Consequences when incorrectly connected to the line supply:
1) For a six–conductor connection to the line supply with DC link connection, the following can occur
immediately or over the medium term:
S
DC link electrolytic capacitors on the power supply will be destroyed
S
Arcing occurs
S
The following burn:
DC link de–coupling diodes
PC board tracks
Note:
2) L
for 5 kW and 10 kW integrated, therefore not necessary here!
k
Fig. 8-37
Examples of illegal (forbidden) six–conductor connection to the line supply + DC link connection
8-320
NE
e.g. NCU PMxx
X181
M500
P500
2U1
1U1
2V1
1V1
2W1
1W1
Twisted
cable
P600
M600
U1
V1 W1
PE
2)
K
Incorrect!
PMxx
Illegal (forbidden)
six–conductor connection
to the line supply with DC
link buffering
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
05.01
MM
PMxx
PMxx
X181
M500
P500
2U1
1U1
2V1
1)
1V1
2W1
1W1